C40K150200

C40K150200 15V@2A

Specification

Input Characteristic

  • Operating Input Range :

    140VAC - 300VAC.

  • Input Frequency :

    50Hz

  • Input Current :

    < 600mA rms @ 140VAC

  • Efficiency :

    > 75% under maximum load @ 230VAC.

  • Inrush Current :

    < 30A Peak @ 230VAC Cold start at 25 Deg.

  • No Load Power :

    < 0.5W at 230VAC input.

Output Characteristic

  • Output Voltage

    15.0 VDC

  • Output Current

    2.0A

  • Line & Load Regulation

    < +/- 5%

  • Ripple

    < 150mV

  • Noise

    < 300mV (measured with 0.1µF ceramic disc & 10µF Electrolytic capacitor across output)

  • Output Over Current

    < 3.5A Max @ 230VC

  • Hold up Time

    > 5 mSec at Full load 100VAC input.
    > 20mSec at Full load 230VAC input

  • Turn-on Delay

    < 1.0 Sec.

  • Rise Time

    < 20 mSec

01 Protections
+

Output over Load and Short ckt Protection

Available

02 Environment
+

Temperature

Operation Ambient 0ºC to +45ºC

Storage -15ºC to +70ºC ambient.

Humidity

Operating 10% RH to 95% RH non-condensing.

Storage 10% RH to 95% RH non-condensing.

03 Product Safety
+

DI-Electric Voltage Withstand Test

3.0KVAC rms, 50Hz INPUT and Shorted OUTPUT Terminals.

Insulation Resistance

When tested with a 500VDC Megger, I.R should be > 100 M Ohms Between Shorted INPUT and Shorted OUTPUT Terminals.

Earth Ground Resistance

The leakage current shall be < 0.25mA for Class II equipment when the power supply is operated at 300VAC input volatge.

04Reliability & Quality
+

Component Derating Factors

All semiconductors junction temperature shall not exceeded the manufacturer's maximum thermal rating.

05EMI / EMC
+

Surge Immunity

As per Test standard IEC61000 - 4 - 5

Test Level 3: +/- 2KV in Differential Mode1

Electrical Fasttransients

As per Test standard IEC61000 - 4 - 4

Test Level 3: 2KV

ESD

As per Test standard IEC61000 - 4 - 2

Test Level 2: Air discharge : 6KV

Test Level 2: Contact Discharge : 4KV

06 Terminations
+

AC Input

AC input through 3-Pin intigrated Indian standard Plug PlasticMoulded Earth Pin.

DC Output

DC Cable 17 Strands/38Swg Gauge wire of 1.5 Mtrs. Length. with 2.5X5.5mm L-Type Locking pin Connector.

07 Indications
+

RED LED Provided to Indicate Adaptor O/P ON

08 Enclosure
+

Dimensions

L = 95.2 mm. W = 52.2 mm. H = 49.7 mm

Material

ABS JET Black Plastic.

AC PIN Material

L & N Brass with Nickel plated. E - Plastic moulded earth Pin.

Weight

150Grams under packed condition

Copyright © 2025 Axiom Power Products Pvt. Ltd. All Right Reserved. Designed by