09:30 AM to 05:30 PM
Call Us: (040) 27266696
Axiom Power Products Pvt. Ltd. Plot No: 195/1 , 2nd floor , Phase-II, IDA, Cherlapaaly, Hyderabad –500051, Telangana, India.

CCMS Power Supply

DAFK050250 (5V@2.50A AC - DC Power Supply with battery back up)

Scope :

The Specification defines the performance characteristics of Lithium-Ion power supply cum battery back up that power up the load and simultaneously charges the built in battery of 3.7V@ 1200mAh capacity.

At the event of AC input Power failure, this battery back up will supply power to the equipment for 1Hr. approx (Power supply load 0.50A) .

Specification

Input Characteristic

  • Input Operating Voltage :

    140VAC - 300VAC.

  • Input Frequency:

    47Hz to 63Hz.

  • Inrush Current :

    < 30A Peak @ 230VAC, Cold start @ 25ºC.

  • Input Current :

    < 0.25A RMS @140VAC.

  • Efficiency :

    > 70% Under Maximum load @ 230VAC.

Output Characteristic

  • Output Voltage

    4.70VDC to 5.50VDC.

  • Output Current

    2.50A Cont.

  • Ripple

    < 100mV. Pk-Pk.

  • Noise

    < 200mV. Pk-Pk.

  • Output Over Current

    > 2.50A to < 5.0A.

  • Battery Charging

    Battery Charging will take place with constant Voltage, Constant current Maximum charging current of the battery is limited to 0.30A ± 10%, Maximum Charging Voltage is set at 4.50V.

01 Protections
+

Over Temperature Protection

The Power supply is protected against over temperature. In case of over temperature the power supply goes to latch mode. the might be return to normal state by AC recycle. This is provided with a large hysteresis to avoid the PCB board over heating incase of fault conditions. the shutdown threshold at the case of Internal Room Ambient Temperature is >70ºC.

Output Overload / Short Circuit Protection

The power supply is protected against over load & short circuit . During over load & Short circuit the power supply will go to hick up mode and resumes to normal operation on removal of fault condition.

Input High Voltage Protection

The Power Supply is protected against input high voltage so it can withstand up to 440VAC supply.

02 Environment
+

Temperature

Operating Ambient 0ºC to + 50ºC. Storage -15ºC to +70ºC ambient.

Humidity

Operating 5% RH to 95% RH non - condensing. Storage 5% RH to 95% RH non- condensing.

04 Product Safety
+

DI-Electric Voltage Withstand Test

1.50KVAC RMS, 50Hz for one minute (trip current set at 5mA) Between Shorted Input and Output terminals.

Insulation Resistance Withstand Test

When tested with 500VDC Megger shall be >100M ohms Between Shorted Input and Output terminals.

05Indications
+

Battery Charging

Amber LED is provided to indicate battery charging.

Battery Full Charged

Green LED is provided to indicate battery full charged.

06Surge Protection
+

4KV Differential mode

07 Terminations
+

AC Input

Input 2core, 0.2Mtr length cable open wires.

DC Output

Output 2core 0.2Mtr length cable open wires.

07 Mechanical
+

Enclosure Dimensions

Length: 124mm, Width: 67.00mm, Height: 39.0mm

Copyright © 2025 Axiom Power Products Pvt. Ltd. All Right Reserved. Designed by